China Fixed Hydrogen Gas Detection Alarm - China Supplier
China Fixed Hydrogen Gas Detection Alarm - China Supplier

Fixed Hydrogen Gas Detection Alarm

Price:Negotiable
Industry Category: Measurement-Analysis-Instruments
Product Category:
Brand: 昆仑海岸
Spec: JQB-G-H2


Contact Info
  • Add:北京市海淀区上地信息路1号1-1号楼A栋8层, Zip:
  • Contact: 张先生
  • Tel:18513004557
  • Email:kunlunhaian@163.com

Other Products

Description
Additional Information

Product Name: Fixed Hydrogen Gas Detection Alarm
Model: JQB-G-H2

Product Description:

JQB-G-H2 Fixed Hydrogen Gas Detection Alarm is a newly developed gas detector by Kunlun Coast, featuring original imported sensors and a new 32-bit low-power processor; dashboard display interface with simultaneous numerical and progress bar display, aesthetically pleasing; 4-layer circuit board wiring for stronger weak signal and anti-interference capabilities; imported 16-bit AD chip and unique signal processing algorithm for higher and more stable measurement accuracy; multiple output signals including 4~20mA, RS485, 200~1000HZ, easily connectable to various alarm controllers, PLC, DCS, and other control systems; explosion-proof structural design suitable for various hazardous industrial environments; widely used in metallurgy, petroleum, petrochemical, municipal, chemical, and other industries.

Fixed Hydrogen Gas Detection Alarm Product Features:

◆ Original imported high-performance sensor, high measurement accuracy, good repeatability, long service life;

◆ 16-bit AD chip, 4-layer circuit board design, stronger weak signal and anti-interference capabilities;

◆ Dashboard display interface design, industry-first, aesthetically pleasing readings, reflecting humanized detail design;

◆ White, orange, and red three-color backlight design, normal and alarm status indication, clear at a glance;

◆ Multiple units selectable: mg/m3, ppm, VOL, LEL;

◆ Embedded 32-bit ultra-low-power processor with unique signal processing algorithm, fast response, stable;

◆ Automatic protection function against high-concentration gas impact, with factory reset to prevent misoperation;

◆ Instrument equipped with infrared remote control, operable via remote control without opening the cover, simple and convenient;

◆ Optional three-wire 4~20mA, RS485, 200~1000HZ signal output, relay output, data recovery, data storage, and other functions;

◆ Two cable entry ports for convenient on-site installation;

◆ Gas chamber structure, easy sensor replacement, no on-site calibration required;

◆ Excellent mechanical design, gas chamber made of military-grade high-strength aluminum profile, wear and corrosion resistant, suitable for complex and harsh industrial environments, reasonable and scientific gas chamber design ensures real-time monitoring accuracy of the sensor;

◆ Explosion-proof rating Exd II CT6, certified by Explosion-proof Electrical Inspection Center.

Technical Specifications:

Name

Description

Detection Gas:

Hydrogen

Detection Principle:

Electrochemical principle

Detection Method:

Fixed online long-term continuous detection, diffusion detection method;

Fixed online continuous detection, via external air pump, achieving pump-suction circulation detection method (air pump optional);

Measurement Range:

0-10ppm, 100ppm, 500ppm, 1000ppm, 2000ppm, 5000ppm (optional, unlisted ranges customizable)

Resolution:

0.01ppm (0-100ppm), 0.1ppm (100-1000ppm), 1ppm (above 1000ppm)

Accuracy:

≤±3% (actual concentration, stricter requirements based on sensor performance)

Operation Method:

Infrared remote control for remote and close-range operation, convenient settings

Repeatability:

≤±1%

Zero Drift:

≤±1% (F.S/year)

Response Time:

≤20 seconds (T90)

Recovery Time:

≤20 seconds

Explosion-proof Mark:

Exd II CT6 Gb

Protection Level:

IP66

Output Signal:

User can determine based on actual on-site environmental needs, can transmit up to 2000 meters (single-core 1mm2 cable)

Three-wire 4-20mA current signal output, connectable to alarm controllers, PLC, DCS, and other control systems (standard configuration)

Digital signal RS-485 output, ModBus RTU communication protocol (optional function)

Frequency signal 200~1000Hz output (optional function)

Two sets of relay output: passive contact capacity 220VAC 0. or 5VDC 0.

Remote transmission of detection data and status alarm via wireless module function (optional function); can achieve Ethernet access

Main Material:

Housing: ADC12 aluminum alloy, sturdy, wear and corrosion resistant (optional 316 stainless steel housing)

Gas chamber: made of high-strength wear and corrosion resistant aluminum profile, sturdy and durable (optional 316 stainless steel gas chamber)

Installation Method:

Wall-mounted pipeline integrated (pipeline external thread specification: M45X1.5mm, optional pipeline adapter screw joint, weldable)

Operating Temperature:

-30℃~+60℃ (special requirements require customization)

Operating Humidity:

≤95%RH, no condensation (humidity >90%RH, condensation can be equipped with filter)

Relative Humidity:

10%~95%RH

Power Supply:

24VDC (normal operating voltage range 12~30VDC)

Power Consumption:

1.5W

Operating Pressure:

≤200Kpa

Dimensions:

180mm*140mm*92mm (H*W*D)

Weight:

Approx. 1.6Kg

Implementation Standards:

GB15322.1-2003, GB3836.1-2010, GB3836.2-2010, GB3836.4-2010

Quality Assurance:

One-year warranty, free repair during warranty period.


Industry Category Measurement-Analysis-Instruments
Product Category
Brand: 昆仑海岸
Spec: JQB-G-H2
Stock:
Origin: China / Beijing / Haidianqu
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192